• DocumentCode
    2389165
  • Title

    Investigation on performances of insulation materials for inverter-fed traction motors

  • Author

    Petrarca, C. ; Egiziano, L. ; Tucci, V. ; Vitelli, M.

  • Author_Institution
    Dipt. di Ingegneria Elettrica, Naples Univ., Italy
  • fYear
    1998
  • fDate
    25-28 Oct 1998
  • Firstpage
    564
  • Abstract
    In order to investigate the degradation phenomena of the electrical insulation of stator windings stressed by non sinusoidal applied voltages, an experimental activity has been carried out on specimen subjected to repetitive unipolar pulse voltages. The effect of the application of such voltages has been studied by recording, at different aging stages, the dielectric properties (ε and tanδ) of the insulating material and by detecting the partial discharge activity when applying a sinusoidal (50 Hz) voltage. Furthermore, the introduction of diagnostic tools based on PD detection has made it possible the classification, recognition and location of defects, which might give the basis for assessing new design criteria and new standards for the electrical insulation of components subjected to distorted wave shapes
  • Keywords
    ageing; dielectric losses; insulation testing; invertors; machine insulation; machine testing; partial discharge measurement; permittivity; stators; traction motors; 50 Hz; PD diagnosis; aging; defect detection; dielectric properties; electrical insulation; inverter-fed traction motor; loss angle; partial discharge; permittivity; stator winding; unipolar pulse voltage; AC motors; Coils; Insulation; Partial discharges; Power system transients; Shape; Stress; Surges; Traction motors; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 1998. Annual Report. Conference on
  • Conference_Location
    Atlanta, GA
  • Print_ISBN
    0-7803-5035-9
  • Type

    conf

  • DOI
    10.1109/CEIDP.1998.732960
  • Filename
    732960