DocumentCode
2395061
Title
The Calibrating Method of Frame-transfer Type CCD Image Smearing
Author
Min, Wei ; HaiNing, Chen ; QinZhang, Wu ; Bin, Xu
Author_Institution
Dept. of Comput. Sci., Chengdu Univ. of Inf. Technol., Chengdu, China
fYear
2010
fDate
7-9 May 2010
Firstpage
4757
Lastpage
4759
Abstract
The Structure and imaging process of frame-transfer CCD is analyzed, Finding the image smearing is because of photosensitive unit is still exposure when image transferred line-by-line, The image subsequent lines will influent by previous lines inevitable, once there is a highlight area in image, which will generate serious image smearing. In this paper, a Calibrate image smearing method is proposed, which uses subsequent line´s gray subtract previous line´s affluence, and use this method to test several frame-transfer type CCD, experimental result shows the method simple and high efficiency.
Keywords
CCD image sensors; image processing; CCD image smearing; calibrating method; frame-transfer; photosensitive unit; Charge coupled devices; Digital cameras; Electron optics; Information technology; Optical imaging; CCD; Calibrating method; component; frame-transfer; image smearing;
fLanguage
English
Publisher
ieee
Conference_Titel
E-Business and E-Government (ICEE), 2010 International Conference on
Conference_Location
Guangzhou
Print_ISBN
978-0-7695-3997-3
Type
conf
DOI
10.1109/ICEE.2010.1195
Filename
5590565