DocumentCode
2399843
Title
Limitation of higher harmonics in Line Start Permanent Magnet Synchronous Motor by star-delta mixed stator winding
Author
Zawilak, T. ; Gwozdziewicz, M.
Author_Institution
Wroclaw University of Technology, ul. Wybrzeze Wyspianskiego 27, 50-370, Poland
fYear
2011
fDate
11-14 April 2011
Firstpage
1
Lastpage
2
Abstract
On the basis of FEM simulations star-delta mixed winding application in Line Start Permanent Magnet Synchronous Motors was investigated. The main goal of star-delta mixed winding in LSPMSM is current higher harmonics limitation. LSPMSM (based on the 90L-4 IM type) FEM model was built. Two stator winding types were utilized: conventional star winding (the same like in the 90L-4 IM type) and star-delta mixed winding. EMF during idle-running and influence of load torque on current higher harmonics were examined.
Keywords
higher harmonics; line start; permanent magnet; winding factor; windings;