• DocumentCode
    2410987
  • Title

    Linear model-based error identification and calibration for data converters

  • Author

    Wegener, Carsten ; Kennedy, Michael Peter

  • Author_Institution
    Dept. of Microelectron. Eng., Univ. Coll. Cork, Ireland
  • fYear
    2003
  • fDate
    2003
  • Firstpage
    630
  • Lastpage
    635
  • Abstract
    For the example of a 12-bit Nyquist-rate ADC, a model for nonlinearity-causing mechanisms is developed based on circuit simulations. The model is used to estimate circuit element values from measured device characteristics. Post-manufacture reconfiguration of the digital control part of the device-type that is used as a test vehicle in this work can improve the linearity performance of a device. An algorithm is proposed that searches for a locally-optimal reconfiguration based on the determined circuit element values. Applying calibration to the circuit simulation model allows one to estimate the performance improvement obtainable with the proposed calibration scheme for a given manufacturing process prior to a physical implementation.
  • Keywords
    analogue-digital conversion; calibration; circuit simulation; errors; 12 bit; ADC; calibration; circuit simulation; data converter; error identification; linear model; nonlinearity; reconfiguration algorithm; Calibration; Circuit simulation; Circuit testing; Digital control; Educational institutions; Feedback loop; Linearity; Manufacturing; Microelectronics; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Design, Automation and Test in Europe Conference and Exhibition, 2003
  • ISSN
    1530-1591
  • Print_ISBN
    0-7695-1870-2
  • Type

    conf

  • DOI
    10.1109/DATE.2003.1253678
  • Filename