• DocumentCode
    2414978
  • Title

    Elimination of leakage effects related to the use of windings with fractions of turns

  • Author

    Perica, Goran

  • Author_Institution
    Sperry Ine., Electronic Systems Dorval, Quebec, Canada
  • fYear
    1984
  • fDate
    18-21 June 1984
  • Firstpage
    268
  • Lastpage
    278
  • Abstract
    Obtaining exact output voltages from transformers is a difficult task due to discrete turns ratios. This becomes even more difficult in modern switching power supplies, operating above 100kHz, because the number of turns per winding is reduced. For multi-channel applications different methods of postregulation have been employed, resulting in increased power dissipation and power supply cost, A new method of dealing with this problem has been developed, offering a higher degree of flexibility. This technique al lows the use of fractions of turns, while maintaining low leakage inductances. Theoretical analysis of leakage effects related to fractional turn windings has been derived and tests on an experimental transformer have been performed.
  • Keywords
    Inductance; Magnetic cores; Magnetic flux; Magnetic switching; Power supplies; Power transformers; Windings;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Specialists Conference, 1984 IEEE
  • Conference_Location
    Gaithersburg, MD, USA
  • ISSN
    0275-9306
  • Type

    conf

  • DOI
    10.1109/PESC.1984.7083488
  • Filename
    7083488