• DocumentCode
    2420034
  • Title

    Radiated emission measurements in completely absorber-lined anechoic chambers without groundplanes

  • Author

    Garn, Heinrich

  • Author_Institution
    Austrian Res. Center, Seibersdorf, Austria
  • fYear
    1989
  • fDate
    23-25 May 1989
  • Firstpage
    390
  • Lastpage
    393
  • Abstract
    A technique is presented for radiated-emission tests in completely absorber-lined chambers which are equipped with floor absorbers instead of groundplanes. Data measured in a completely absorber-lined chamber can be converted to open-site equivalents with an accuracy of ±0.5 dB (30-1000 MHz) by applying the conversion factors given. The great advantage of this technique is that tests are performed with fixed position of the receiving antenna. There is no need for the time-consuming height scan, which is a major source of errors in tests performed in semianechoic chambers
  • Keywords
    anechoic chambers; electric variables measurement; electromagnetic interference; 30 to 1000 MHz; EMI; UHF; VHF; completely absorber-lined anechoic chambers; conversion factors; fixed position; floor absorbers; open-site equivalents; radiated emission measurement; radiated-emission tests; receiving antenna; Anechoic chambers; Antenna accessories; Current distribution; Dipole antennas; Loaded antennas; Loss measurement; Propagation losses; Receiving antennas; Testing; Transmitting antennas;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1989., IEEE 1989 National Symposium on
  • Conference_Location
    Denver, CO
  • Type

    conf

  • DOI
    10.1109/NSEMC.1989.37216
  • Filename
    37216