• DocumentCode
    2420403
  • Title

    Towards a discretely actuated steerable cannula

  • Author

    Ayvali, Elif ; Desai, Jaydev P.

  • Author_Institution
    Dept. of Mech. Eng., Univ. of Maryland, College Park, MD, USA
  • fYear
    2012
  • fDate
    14-18 May 2012
  • Firstpage
    1614
  • Lastpage
    1619
  • Abstract
    Several percutaneous needle-based and intravascular procedures require guidance of the diagnostic or therapeutic tool to the target location by maneuvering the needle or catheter to correct for the error in reaching the target location. Hence, in this paper we present our work towards developing a discretely actuated steerable needle/cannula with multiple degrees-of-freedom to `steer´ the cannula by discrete actuation along the cannula length. We are interested in using the cannula to introduce both diagnostic and therapeutic tools, which may otherwise be difficult to deliver to the appropriate location. We use two antagonistic SMA wires as actuators to generate the required bending forces at each joint. SMA wires were annealed through a customized training process to an arc shape and mounted in the machined grooves on the outer surface of the cannula to generate local bending upon thermal actuation. We propose to use temperature feedback to control the position of the SMA actuators. To use temperature feedback as the feedback signal for enabling individual joint actuation, we had to fully characterize the SMA actuator. Classical uniaxial testing devices and experimental setup used in characterizing straight annealed SMA wires are not applicable in this work since the SMA wire is annealed in an arbitrary shape. Hence, we also present an experimental setup and a procedure for characterizing an SMA actuator that transforms into an arc shape upon thermal actuation.
  • Keywords
    actuators; feedback; medical robotics; needles; position control; signal processing; wires; SMA actuators; antagonistic SMA wires; arc shape; cannula length; catheter maneuvering; customized training process; diagnostic tools; discretely actuated steerable cannula; feedback signal; machined grooves; needle maneuvering; percutaneous intravascular procedures; percutaneous needle-based procedures; position control; shape memory alloy; temperature feedback; therapeutic tools; thermal actuation; uniaxial testing devices; Actuators; Annealing; Needles; Shape; Strain; Stress; Wires;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Robotics and Automation (ICRA), 2012 IEEE International Conference on
  • Conference_Location
    Saint Paul, MN
  • ISSN
    1050-4729
  • Print_ISBN
    978-1-4673-1403-9
  • Electronic_ISBN
    1050-4729
  • Type

    conf

  • DOI
    10.1109/ICRA.2012.6225312
  • Filename
    6225312