• DocumentCode
    2433795
  • Title

    JEDEC “TCR” interlaboratory experiment-lessons learned

  • Author

    Schafft, Harry A. ; Suehle, John S. ; Albers, John

  • Author_Institution
    Nat. Inst. of Stand. & Technol., Gaithersburg, MD, USA
  • fYear
    1994
  • fDate
    16-19 Oct 1994
  • Firstpage
    12
  • Lastpage
    19
  • Abstract
    Describes the results of an interlaboratory experiment involving wafer-level measurements intended to do the following: 1) to determine the precision and bias of both the JEDEC Standard Test Method (JESD33) for determining the temperature coefficient of resistance (TCR) and joule heating of a metal line and the ASTM standard (F1261) for measuring the electrical width of a metal line; 2) to assess the reproducibility of measuring the temperature drop across the interface between the silicon substrate and the hot chuck; and 3) to obtain a temperature calibration of the hot chucks used by the participating laboratories
  • Keywords
    integrated circuit measurement; integrated circuit metallisation; integrated circuit reliability; integrated circuit testing; temperature measurement; thermal resistance; ASTM standard; F1261; IC reliability; JEDEC Standard Test Method; JESD33; electrical width; hot chuck; interlaboratory experiment; joule heating; metal line; temperature calibration; temperature coefficient of resistance; temperature drop; wafer-level measurements; Electric resistance; Electric variables measurement; Electrical resistance measurement; Measurement standards; Particle measurements; Reproducibility of results; Resistance heating; Silicon; Temperature measurement; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Integrated Reliability Workshop, 1994. Final Report., 1994 International
  • Conference_Location
    Lake Tahoe, CA
  • Print_ISBN
    0-7803-1908-7
  • Type

    conf

  • DOI
    10.1109/IRWS.1994.515821
  • Filename
    515821