• DocumentCode
    2450534
  • Title

    SunSine300, utility interactive AC module anti-islanding test results

  • Author

    Kern, Gregory A.

  • Author_Institution
    Ascension Technol. Inc., Boulder, CO, USA
  • fYear
    1997
  • fDate
    29 Sep-3 Oct 1997
  • Firstpage
    1265
  • Lastpage
    1268
  • Abstract
    Test results are presented for the SunSine300 AC photovoltaic module´s anti-islanding protection. These tests were conducted on a single SunSine300 AC module inverter under controlled laboratory conditions. The various passive and active anti-islanding methods used in the SunSine300 are discussed. Other forms of anti-islanding protection are also discussed. Data is presented to show how tightly matched the PV and load must be for special islanding detection methods to be needed. The data also shows how effectively our proprietary Zebra method of anti-islanding performs. In all of the trip tests conducted, the SunSine300 never exhibited run-on. In this paper, run-on is defined as operation into an islanded load longer than 2 seconds
  • Keywords
    invertors; protection; solar cell arrays; SunSine300; Zebra method; anti-islanding protection; anti-islanding test results; controlled laboratory conditions; utility interactive AC module; Frequency; Inverters; Photovoltaic systems; Protection; Research and development; Research and development management; Solar power generation; Technology management; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Photovoltaic Specialists Conference, 1997., Conference Record of the Twenty-Sixth IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    0160-8371
  • Print_ISBN
    0-7803-3767-0
  • Type

    conf

  • DOI
    10.1109/PVSC.1997.654318
  • Filename