DocumentCode
2450534
Title
SunSine300, utility interactive AC module anti-islanding test results
Author
Kern, Gregory A.
Author_Institution
Ascension Technol. Inc., Boulder, CO, USA
fYear
1997
fDate
29 Sep-3 Oct 1997
Firstpage
1265
Lastpage
1268
Abstract
Test results are presented for the SunSine300 AC photovoltaic module´s anti-islanding protection. These tests were conducted on a single SunSine300 AC module inverter under controlled laboratory conditions. The various passive and active anti-islanding methods used in the SunSine300 are discussed. Other forms of anti-islanding protection are also discussed. Data is presented to show how tightly matched the PV and load must be for special islanding detection methods to be needed. The data also shows how effectively our proprietary Zebra method of anti-islanding performs. In all of the trip tests conducted, the SunSine300 never exhibited run-on. In this paper, run-on is defined as operation into an islanded load longer than 2 seconds
Keywords
invertors; protection; solar cell arrays; SunSine300; Zebra method; anti-islanding protection; anti-islanding test results; controlled laboratory conditions; utility interactive AC module; Frequency; Inverters; Photovoltaic systems; Protection; Research and development; Research and development management; Solar power generation; Technology management; Testing; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Photovoltaic Specialists Conference, 1997., Conference Record of the Twenty-Sixth IEEE
Conference_Location
Anaheim, CA
ISSN
0160-8371
Print_ISBN
0-7803-3767-0
Type
conf
DOI
10.1109/PVSC.1997.654318
Filename
654318
Link To Document