• DocumentCode
    2453961
  • Title

    Accurate AC measurement of the in-phase component of DC standard resistances

  • Author

    Tadros, N.N.

  • Author_Institution
    Nat. Inst. of Stand., Giza, Egypt
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    400
  • Lastpage
    401
  • Abstract
    A guarded AC voltage comparator bridge has been devised for the precise measurement of the in-phase component of DC standard resistances over the frequency range 10 Hz-100 Hz. It is based on inductive voltage dividers with electronically increased input impedance. The AC behavior of the resistance standards maintaining the NIS Ohm, as well as the working standards of values 1 /spl Omega/ to 10 k/spl Omega/, were investigated using this bridge.
  • Keywords
    bridge circuits; bridge instruments; comparators (circuits); electric resistance measurement; measurement standards; voltage dividers; 1 ohm to 10 kohm; 10 to 100 Hz; AC measurement; DC standard resistances; NIS Ohm; electronically increased input impedance; frequency range; guarded AC voltage comparator bridge; in-phase component; inductive voltage dividers; resistance standards; working standards; AC generators; Bridge circuits; Electrical resistance measurement; Equations; Frequency measurement; Impedance; Measurement standards; Phase measurement; Resistors; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.547134
  • Filename
    547134