• DocumentCode
    2457937
  • Title

    Experiment study on preventing and extinguishing fire using stopping agent

  • Author

    Sun, Chengkun ; Yao, Jian ; Tian, Dongmei

  • Author_Institution
    Fac. of Recourses & Safety Eng., China Univ. of Min. & Technol., Beijing, China
  • fYear
    2011
  • fDate
    24-26 June 2011
  • Firstpage
    4035
  • Lastpage
    4037
  • Abstract
    In order to solve the problem of low efficiency for preventing and extinguishing fire, the principle of preventing and extinguishing fire using stopping agent was analyzed. Affusing liquid system for Coal seam was founded in the scene through selecting many stopping agents to experiment. The result showed Na2CO3 which concentration is 10 percent was the better reasonable as stopping agent of preventing and extinguishing fire for coal seam. It have good effect with checkout in the scene. This result provide science basis for preventing and extinguishing fire.
  • Keywords
    coal; flameproofing; Na2CO3; coal seam; fire extinguish; fire prevention; liquid system; stopping agent; Coal; Coal mining; Combustion; Educational institutions; Electronic mail; Fires; coal seam affusing water; fire; preventing and extinguishing fire; stopping agent;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Remote Sensing, Environment and Transportation Engineering (RSETE), 2011 International Conference on
  • Conference_Location
    Nanjing
  • Print_ISBN
    978-1-4244-9172-8
  • Type

    conf

  • DOI
    10.1109/RSETE.2011.5965205
  • Filename
    5965205