• DocumentCode
    2458833
  • Title

    Radiated fields from unknown sources

  • Author

    Lao, R.R. ; Chi, C.M. ; Shay, W.T. ; Ma, M.T.

  • Author_Institution
    Center for Meas. Stand., Ind. Technol. Res. Inst., Hsinchu, Taiwan
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    447
  • Lastpage
    448
  • Abstract
    Preliminary results of electric fields radiated from an unknown source, obtained by measurements inside a TEM cell, in an anechoic chamber, and above an open site based on available theories, are analyzed to confirm their equivalence. Either one of these three can be recommended as the standard for Taiwan industry.
  • Keywords
    anechoic chambers; electric field measurement; electromagnetic interference; measurement standards; TEM cell; Taiwan industry; anechoic chamber; electric fields; open site; radiated fields; standard; unknown sources; Abstracts; Anechoic chambers; Electric variables measurement; Feeds; Frequency estimation; Magnetic field measurement; Measurement standards; Polarization; Power measurement; TEM cells;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.547159
  • Filename
    547159