Abstract
The authors investigate a novel insulator concept which involves the use of alternating layers of conductors and insulators with periods less than 1 mm. These structures perform many times better (about 1.5 to 4 times higher breakdown electric field) than conventional insulators in long pulse, short pulse and alternating polarity applications. They present their ongoing studies investigating the degradation of the breakdown electric field resulting from surface roughness, the effect of gas pressure and the performance of the insulator structure under bipolar stress. Further, they present their initial modeling studies
Keywords
electric breakdown; electric strength; insulator testing; surface topography; alternating conducting/insulating layers; applications; breakdown electric field; breakdown field degradation; gas pressure; insulation performance; modeling studies; multilayer ultra-high gradient insulator technology; surface roughness; Bonding; Breakdown voltage; Degradation; Dielectrics and electrical insulation; Electric breakdown; Flashover; Gold; Nonhomogeneous media; Silicon compounds; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Discharges and Electrical Insulation in Vacuum, 1998. Proceedings ISDEIV. XVIIIth International Symposium on
Conference_Location
Eindhoven
ISSN
1093-2941
Print_ISBN
0-7803-3953-3
Type
conf
DOI
10.1109/DEIV.1998.738868
Filename
738868
Link To Document