DocumentCode
2466074
Title
Fault locaiton in a DC Marine power system
Author
Ke Jia ; Christopher, E. ; Sumner, M. ; Thomas, David
Author_Institution
Dept. of Electr. Eng., Univ. of Nottingham, Nottingham, UK
fYear
213
fDate
10-13 June 213
Firstpage
1
Lastpage
4
Abstract
This paper introduced a fault localization method in DC Marine power system using multiple injections at two different locations. The experimental test results which were derived from a 30kW, 400V twin bus DC marine system demonstrator show that a fault can be located accurately regardless of the existence of system passive filters.
Keywords
fault location; marine power systems; passive filters; power distribution; DC marine power system; fault localization method; multiple injections; power 30 kW; system passive filters; twin bus DC marine system demonstrator; voltage 400 V; Injection; Marine power system; fault location;
fLanguage
English
Publisher
iet
Conference_Titel
Electricity Distribution (CIRED 2013), 22nd International Conference and Exhibition on
Conference_Location
Stockholm
Electronic_ISBN
978-1-84919-732-8
Type
conf
DOI
10.1049/cp.2013.0541
Filename
6683144
Link To Document