  • Abstract
    This paper introduced a fault localization method in DC Marine power system using multiple injections at two different locations. The experimental test results which were derived from a 30kW, 400V twin bus DC marine system demonstrator show that a fault can be located accurately regardless of the existence of system passive filters.