• DocumentCode
    2468798
  • Title

    Measuring current emission and work functions of large thermionic cathodes

  • Author

    Fortgang, Clifford M.

  • Author_Institution
    Los Alamos Nat. Lab., NM, USA
  • fYear
    2002
  • fDate
    2002
  • Firstpage
    298
  • Lastpage
    299
  • Abstract
    We have constructed a small facility called the Cathode Test Stand (CTS) to investigate engineering and physics issues regarding large thermionic dispenser-cathodes. In particular, we have looked at the issues of temperature uniformity on the cathode surface and cathode quality as measured by its work function. We have done thermal imaging of both 8" and 6.5" cathodes. Here we report on measurements of the cathode work function, both the average value and how it varies across the face of the cathode.
  • Keywords
    infrared imaging; thermionic cathodes; work function; 6.5 in; 8 in; Cathode Test Stand; current emission; measurement technique; surface temperature uniformity; thermal imaging; thermionic dispenser-cathode; work function; Cathodes; Current measurement; Distribution functions; Explosives; Laboratories; Linear particle accelerator; Radiography; Surface fitting; Temperature sensors; Thermionic emission;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Vacuum Electronics Conference, 2002. IVEC 2002. Third IEEE International
  • Print_ISBN
    0-7803-7256-5
  • Type

    conf

  • DOI
    10.1109/IVELEC.2002.999388
  • Filename
    999388