  • Abstract
    High-frequency (HF) ultrasound imaging has been shown to be useful for imaging anatomical structures of the eye and small animals in biological and pharmaceutical research, achieving good spatial resolution at an affordable price. Cardiovascular research utilizing mice requires not only real-time B-scan imaging, but also ultrasound Doppler to evaluate both movements and blood flow of the mouse heart. In this paper, we report the development of the first real-time duplex HF ultrasound system with both B-scan imaging and Doppler imaging, using a 30 MHz 64-element linear array. The system included a HF pulsed-wave Doppler module, a 16-channel HF analog beamformer module, a PC with a 200 MS/s 14-bit PCI A/D card, and real-time Labview software. Both a wire phantom and a micro flow phantom were used to evaluate system performance. The system has a lateral resolution better than 160 urn and is capable of measuring motion velocity as low as 0.1 mm/s and as high as 1 m/s. B-scan images of excised rabbit eyes have been achieved, as well as clear blood flow velocity profiles in mouse superficial vessels with diameters of 200 mum and major aortas. The system is able to acquire real-time B-mode and Doppler images. The system will also have the capability of acquiring 400 B-mode images per second. In vivo zebrafish and mouse experiment results show a promising future of this system in small animal research.
  • Keywords
    biomedical ultrasonics; blood vessels; cardiology; haemodynamics; medical image processing; phantoms; B-scan imaging; anatomical structure imaging; blood flow velocity; duplex ultrasound imaging; frequency 30 MHz; microflow phantom; mouse superficial vessels; organ movements; small animal research; ultrasound Doppler imaging; wire phantom; Anatomical structure; Animals; Biomedical imaging; Blood flow; Hafnium; High-resolution imaging; Imaging phantoms; Mice; Real time systems; Ultrasonic imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2007. IEEE
  • Conference_Location
    New York, NY
  • ISSN
    1051-0117
  • Print_ISBN
    978-1-4244-1384-3
  • Electronic_ISBN
    1051-0117
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2007.94
  • Filename
    4409667