DocumentCode
2474942
Title
Multi-factor ageing of stator coil insulation of HV machines and degree of correlation among non-destructive test parameters
Author
Mallikarjunappa, K. ; Viswanatha, C. ; Moorching, S.N.
Author_Institution
Central Power Res. Inst., Bangalore, India
fYear
1993
fDate
17-20 Oct 1993
Firstpage
562
Lastpage
567
Abstract
Multifactor accelerated ageing studied have been carried out on scaled-down model coils of an 11-kV insulation system. The test parameters tan delta tip-up (δT), capacitance tip-up (ΔC/C), integrated discharge energy (IDE), and discharge inception voltage (Vi) were monitored at regular intervals during the ageing period to characterize the ageing processes. Attempts have been made to find the correlation between different test parameters as a function of ageing time. A good correlation is found to exist between δT and δC/C. The degree of correlation between different test parameters tends to increase as the ageing proceeds
Keywords
ageing; insulation testing; insulator testing; life testing; stators; 11 kV; 11-kV insulation system; HV machines; ageing processes; capacitance tip-up; degree of correlation; discharge inception voltage; integrated discharge energy; multifactor accelerated ageing; stator coil insulation; tan delta tip-up; test parameters; Aging; Capacitance; Coils; Condition monitoring; Dielectrics and electrical insulation; Insulation testing; Nondestructive testing; Power system reliability; Stators; Thermal stresses;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 1993. Annual Report., Conference on
Conference_Location
Pocono Manor, PA
Print_ISBN
0-7803-0966-9
Type
conf
DOI
10.1109/CEIDP.1993.378913
Filename
378913