DocumentCode
2475839
Title
P1A-6 Versatile High Frequency Coded Imaging System
Author
Lewandowski, Marcin ; Nowicki, Andrzej
Author_Institution
Polish Acad. of Sci. Warsaw, Warsaw
fYear
2007
fDate
28-31 Oct. 2007
Firstpage
1262
Lastpage
1265
Abstract
Coded transmission is an approach to solve the inherent compromise between penetration and resolution required in ultrasound imaging. It is widely acknowledged that this technique gives major improvement in SNR and enables higher contrast imaging without sacrificing the resolution. A novel HF (20-35 MHz) ultrasound real-time imaging system for research and evaluation of the coded transmission was developed. The digital programmable coder-digitizer module based on the field programmable gate array (FPGA) chip supports arbitrary waveform coded transmission and RF echoes sampling up to 200 MSPS, as well as real-time streaming of digitized RF data via a high speed USB interface to the PC. All RF and image data processing was implemented in the software. A novel balanced software architecture supports real-time processing and display at rates up to 30 frames/sec. Verified system was used to gather data for sine burst and 16-bit Golay code excitation using a single element scanning head with thick film focused spherical transducer 25 MHz center frequency and 56% system bandwidth. SNR gain for the Golay codes (referenced to single burst) of 15 dB for 20 MHz and 16 dB for 35 MHz were obtained. In water the axial resolution for both single burst and the Golay codes was the same FWMH=20 ns at 20 MHz and FWMH=15 ns at 35 MHz. The presented system is a practical and low cost implementation of coded excitation technique in HF ultrasound imaging that can be used as a research tool as well as to be introduced into production.
Keywords
Golay codes; acoustic signal processing; field programmable gate arrays; real-time systems; ultrasonic imaging; ultrasonic transducers; ultrasonic transmission; 16-bit Golay code excitation; RF echoes; coded transmission; digital programmable coder-digitizer module; field programmable gate array; frequency 20 MHz to 35 MHz; high frequency coded imaging system; higher contrast imaging; software architecture; thick film focused spherical transducer; ultrasound real-time imaging system; Field programmable gate arrays; Hafnium; High-resolution imaging; Image resolution; Image sampling; Radio frequency; Real time systems; Streaming media; Ultrasonic imaging; Universal Serial Bus;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium, 2007. IEEE
Conference_Location
New York, NY
ISSN
1051-0117
Print_ISBN
978-1-4244-1384-3
Electronic_ISBN
1051-0117
Type
conf
DOI
10.1109/ULTSYM.2007.317
Filename
4409890
Link To Document