• DocumentCode
    2480832
  • Title

    P5B-6 In Vitro Pressure Estimation Obtained from Subharmonic Contrast Microbubble Signals

  • Author

    Leodore, Lauren M. ; Forsberg, Flemming ; Shi, William T.

  • Author_Institution
    Thomas Jefferson Univ., Philadelphia
  • fYear
    2007
  • fDate
    28-31 Oct. 2007
  • Firstpage
    2207
  • Lastpage
    2210
  • Abstract
    The long term goal of this project is to monitor and quantifyintra-cardiac pressures via contrast-enhanced subharmonic imaging. Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based contrast agent signals for the noninvasive estimation of hydrostatic blood pressures in heart cavities and major blood vessels. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled confocally at a 60deg angle to each other. Changes in the first, second, and subharmonic amplitudes of the contrast agents Sonazoid, Optison, Definity, PRC-1 and Levovist were measured in vitro over a pressure range from 0 to 186 mmHg using a sealed 2.25 L water tank that can sustain pressure changes in excess of 200 mmHg. Over the pressure range studied the first and second harmonic amplitudes reduced only approximately 2.4 dB and 1.8 dB in vitro. Over the same pressure range, the subharmonic amplitudes of the agents decreased between 9.6 and 13 dB. Excellent linear regressions (r > 0.98; p > 0.001) were achieved between the subharmonic amplitude and hydrostatic pressure for all five agents tested. In conclusion, the subharmonic microbubble signal component is a good indicator of the hydrostatic pressure variation in vitro. SHAPE offers the possibility of allowing pressure gradients in the heart to be obtained noninvasively. Future studies will include in vivo pressure measurements.
  • Keywords
    biomedical transducers; biomedical ultrasonics; blood pressure measurement; blood vessels; bubbles; cardiovascular system; harmonics; regression analysis; ultrasonic transducers; Definity contrast agent; Levovist; Optison; Sonazoid contrast agent; contrast-enhanced subharmonic imaging; first harmonic amplitudes; heart cavities; hydrostatic blood pressure estimation; hydrostatic pressure variation; in vitro SHAPE construction; in vitro pressure estimation; in vivo pressure measurements; intra-cardiac pressure quantification; linear regression; major blood vessels; microbubble-based contrast agent signals; pressure 0 mm Hg to 186 mm Hg; second harmonic amplitudes; single-element transducers; subharmonic aided pressure estimation; subharmonic contrast microbubble signals; Assembly systems; Biomedical imaging; Biomedical monitoring; Blood pressure; Blood vessels; Heart; In vitro; Pressure measurement; Shape; Transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2007. IEEE
  • Conference_Location
    New York, NY
  • ISSN
    1051-0117
  • Print_ISBN
    978-1-4244-1384-3
  • Electronic_ISBN
    1051-0117
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2007.555
  • Filename
    4410128