• DocumentCode
    2483969
  • Title

    Low voltage standards in the 10 Hz to 1 MHz range

  • Author

    Oldham, N. ; Parker, M. ; Waltrip, B. ; Avramov-Zamurovic, S.

  • Author_Institution
    Electr. Div., Nat. Inst. of Stand. & Technol., Gaithersburg, MD, USA
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    570
  • Lastpage
    571
  • Abstract
    A step down procedure is described for establishing voltage standards in the 1 mV to 100 mV range at frequencies between 10 Hz and 1 MHz. The step down employs low voltage thermal voltage converters and micropotentiometers. Techniques are given for measuring input impedance and calculating loading errors.
  • Keywords
    measurement errors; measurement standards; potentiometers; voltage measurement; 1 to 100 mV; 10 Hz to 1 MHz; loading errors; low voltage standards; low voltage thermal voltage converters; measuring input impedance; micropotentiometers; voltage standards; Capacitance; Digital-to-frequency converters; Electric resistance; Electrical resistance measurement; Frequency conversion; Impedance measurement; Low voltage; NIST; Signal generators; Uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.547354
  • Filename
    547354