• DocumentCode
    2491268
  • Title

    SLAC modulator system improvements and reliability results

  • Author

    Donaldson, A.R.

  • Author_Institution
    Linear Accel. Center, Stanford Univ., CA, USA
  • fYear
    1998
  • fDate
    22-25 Jun 1998
  • Firstpage
    74
  • Lastpage
    79
  • Abstract
    In 1995, an improvement project was completed on the 244 klystron modulators in the linear accelerator. This article offers project details and their resulting effect on modulator and component reliability. Prior to the project, we had collected four operating cycles (1991 through 1995) of MTTF data. In this discussion, the ´91 data will be excluded since the modulators operated at 60 Hz. The five periods following the ´91 run were reviewed due to the common repetition rate at 120 Hz
  • Keywords
    electron accelerators; klystrons; linear colliders; modulators; reliability; SLAC modulator system improvements; component reliability; klystron modulators; linear accelerator; modulator system; operating cycles; reliability results; repetition rate; Anodes; Klystrons; Linear accelerators; Optical modulation; Pulse transformers; Pulse width modulation; Safety; Space vector pulse width modulation; Superluminescent diodes; Thyratrons;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Modulator Symposium, 1998. Conference Record of the 1998 Twenty-Third International
  • Conference_Location
    Rancho Mirage, CA
  • ISSN
    1076-8467
  • Print_ISBN
    0-7803-4244-5
  • Type

    conf

  • DOI
    10.1109/MODSYM.1998.741195
  • Filename
    741195