Correction of systematic errors in automatically produced boundaries from low-contrast ventriculograms
Author
Suri, Jasjit S. ; Haralick, Robert M. ; Sheehan, Florence H.
Author_Institution
Dept. of Electr. Eng., Washington Univ., Seattle, WA, USA
Volume
4
fYear
1996
fDate
25-29 Aug 1996
Firstpage
361
Abstract
Poor contrast in the apex zone and nonhomogeneous mixing of the dye with the blood in the left ventricle causes the left ventricle pixel-based classifiers operating on ventriculograms to yield boundaries which are not close to ground truth boundaries as delineated by the cardiologist. They have a mean boundary error of about 6.4 mm and an error of about 12.5 mm in the apex zone. These errors have a systematic positional and orientational bias, the boundary being under-estimated in the apex zone. This paper discusses two calibration methods: the identical coefficient and the independent coefficient to remove these systematic biases. From these methods, we constitute a combined algorithm which reduces the boundary error compared to either of the calibration methods. The algorithm, in a greedy way, computes which and how many vertices of the left ventricle boundary can be taken from the computed boundary of each method to best improve the performance. The corrected boundaries have a mean error of less than 3.5 mm with a standard deviation of 3.4 mm over the approximately 6×104 vertices in the data set of 291 studies. Our methodology reduces the mean boundary error by 2.9 millimeters over the boundary produced by the classifier. We also show the calibration algorithm performs better in the apex zone where the dye is unable to reach. For end-diastole, it reduces the error in the apex zone by 8.5 millimeters over the pixel-based classifier boundaries
Keywords
calibration; cardiology; diagnostic radiography; edge detection; error correction; image classification; medical image processing; apex zone; automatically produced boundaries; blood; calibration algorithm; calibration methods; cardiology; dye; end-diastole; greedy algorithm; heart; left ventricle pixel-based classifiers; low-contrast ventriculograms; mean boundary error; nonhomogeneous mixing; systematic error correction; systematic orientational bias; systematic positional bias; under-estimated boundary; Blood; Calibration; Cardiology; Databases; Error correction; Heart; Intelligent systems; Laboratories; Motion analysis; Noise level;
fLanguage
English
Publisher
ieee
Conference_Titel
Pattern Recognition, 1996., Proceedings of the 13th International Conference on
Conference_Location
Vienna
ISSN
1051-4651
Print_ISBN
0-8186-7282-X
Type
conf
DOI
10.1109/ICPR.1996.547446
Filename
547446
Link To Document