DocumentCode
2509649
Title
Magamp post regulators-practical design considerations to allow operation under extreme loading conditions
Author
Lee, Jeyull ; Chen, Dan Y. ; Jamerson, Cliff
Author_Institution
Dept. of Electr. Eng., Virginia Polytech. Inst. & State Univ., Blacksburg, VA, USA
fYear
1988
fDate
1-5 Feb 1988
Firstpage
368
Lastpage
376
Abstract
Practical design equations and guidelines to allow magamp operation under extreme loading conditions are established. Three conditions are considered: shutdown of output, foldback of the output current, and operation under discontinuous-inductor-current mode. Several numerical examples are used to illustrate design considerations and the use of the design equations
Keywords
magnetic amplifiers; discontinuous-inductor-current mode; extreme loading conditions; magamp post regulators; output current foldback; output shutdown; Circuits; Equations; Inductors; Magnetic separation; Magnetic switching; Pulse width modulation; Regulators; Saturation magnetization; Switches; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Applied Power Electronics Conference and Exposition, 1988. APEC '88. Conference Proceedings 1988., Third Annual IEEE
Conference_Location
New Orleans, LA
Type
conf
DOI
10.1109/APEC.1988.10585
Filename
10585