• DocumentCode
    2509649
  • Title

    Magamp post regulators-practical design considerations to allow operation under extreme loading conditions

  • Author

    Lee, Jeyull ; Chen, Dan Y. ; Jamerson, Cliff

  • Author_Institution
    Dept. of Electr. Eng., Virginia Polytech. Inst. & State Univ., Blacksburg, VA, USA
  • fYear
    1988
  • fDate
    1-5 Feb 1988
  • Firstpage
    368
  • Lastpage
    376
  • Abstract
    Practical design equations and guidelines to allow magamp operation under extreme loading conditions are established. Three conditions are considered: shutdown of output, foldback of the output current, and operation under discontinuous-inductor-current mode. Several numerical examples are used to illustrate design considerations and the use of the design equations
  • Keywords
    magnetic amplifiers; discontinuous-inductor-current mode; extreme loading conditions; magamp post regulators; output current foldback; output shutdown; Circuits; Equations; Inductors; Magnetic separation; Magnetic switching; Pulse width modulation; Regulators; Saturation magnetization; Switches; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference and Exposition, 1988. APEC '88. Conference Proceedings 1988., Third Annual IEEE
  • Conference_Location
    New Orleans, LA
  • Type

    conf

  • DOI
    10.1109/APEC.1988.10585
  • Filename
    10585