• DocumentCode
    2510771
  • Title

    Analysis of Delphos 300 kW connected PV plant after the first year of operation

  • Author

    Albergamo, V. ; Fabriani, L. ; Gentilin, L. ; Messina, G. ; Romanazzo, M. ; Sarno, A.

  • Author_Institution
    ENEA, Rome, Italy
  • fYear
    1988
  • fDate
    1988
  • Firstpage
    1267
  • Abstract
    A summary of design specifications and operational data collected from February until August 1987 using the MINIDAS data-acquisition system are presented for a 300 kW peak power experimental PV plant aimed at demonstration and testing of components and systems, with emphasis on reliability, lifetime, maintenance, and operational problems. Recorded data are transferred to a PDP 11 computer system for statistical processing and presentation. The data show that the plant reached a maximum power of 310 kW on a very clean and cold day in April at a solar radiation of about 1020 W/m2. It is shown that the field arrangement produces a power rate per unit area of 77 Wp/m2/.
  • Keywords
    data acquisition; electrical engineering computing; solar power stations; 300 kW; 310 kW; Delphos PV plant; MINIDAS data-acquisition system; PDP 11 computer system; maintenance; operational data; reliability; solar radiation; statistical processing; testing; Europe; Life testing; Maintenance; Notice of Violation; Power system reliability; Silicon; Solar radiation; System testing; Voltage; Wiring;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Photovoltaic Specialists Conference, 1988., Conference Record of the Twentieth IEEE
  • Conference_Location
    Las Vegas, NV, USA
  • Type

    conf

  • DOI
    10.1109/PVSC.1988.105908
  • Filename