• DocumentCode
    2510775
  • Title

    A GATE Monte Carlo Simulation of the Performance of a High-Sensitivity and High-Resolution LSO Based Small Animal PET Camera

  • Author

    Baghaei, Hossain ; Zhang, Yuxuan ; Li, Hongdi ; Wang, Yu ; Kim, Soonseok ; Ramirez, Rocio ; Liu, Jiguo ; Liu, Shitao ; Wong, Wai-Hoi

  • Author_Institution
    M. D. Anderson Cancer Center, Texas Univ., Houston, TX
  • Volume
    4
  • fYear
    2006
  • fDate
    Oct. 29 2006-Nov. 1 2006
  • Firstpage
    2476
  • Lastpage
    2479
  • Abstract
    A Monte Carlo simulation of the performance of a high-sensitivity and high-resolution small animal PET scanner with large axial field-of-view (AFOV) is presented. The simulated camera is based on the photomultiplier-quadrant-sharing technique and composed of 180 blocks of 14 times 14 LSO crystals (each crystal is 1.16 times 1.27 times 10 mm3). The designed camera consists of 84 detector rings with an AFOV of 11.6 cm and ring diameter of 16.6 cm. For simulation, we used GATE (Geant4 Application for Tomographic Emission) simulation package. GATE is a GEANT4 based software toolkit for realistic simulation of PET and SPECT systems. In this study, we first validated GATE by comparing its prediction for spatial resolution, absolute sensitivity, NEC, and images of the Data Spectrum Micro Deluxe phantom with the measured data using an existing BGO small animal PET scanner which is also based on the photomultiplier-quadrant-sharing technique and has similar AFOV and ring diameter. Spatial resolution simulation was done for point sources located at the center of the camera and also off the center. Simulation data suggest that new LSO scanner could have a reconstructed radial (tangential) spatial resolution of 1.14 (1.14) mm, 1.31 (1.32) mm, 1.54 (1.52) mm, 2.01 (1.8) mm at the center, and 1 cm, 2 cm and 3 cm off the center, respectively. It predicts that 1.2 mm hot rod inserts in the Micro Deluxe phantom will be distinguishable. Simulation predicts an absolute sensitivity of about 6.
  • Keywords
    Monte Carlo methods; positron emission tomography; 16.6 cm; Data Spectrum Micro Deluxe phantom; GATE simulation package; Geant4 Application for Tomographic Emission; Monte Carlo simulation; photomultiplier-quadrant-sharing technique; positron emission tomography; small animal PET camera; Animals; Application software; Cameras; Crystals; Detectors; Imaging phantoms; Packaging; Positron emission tomography; Software tools; Spatial resolution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2006. IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1095-7863
  • Print_ISBN
    1-4244-0560-2
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2006.354413
  • Filename
    4179527