    Empirical Dual Energy Calibration (EDEC) for Cone-Beam Computed Tomography

  • Author

    Kachelriess, Marc ; Berkus, Timo ; Stenner, Philip ; Kalender, Willi A.

  • Author_Institution
    Inst. of Med. Phys., Erlangen Univ.
  • Volume
    4
  • fYear
    2006
  • fDate
    Oct. 29 2006-Nov. 1 2006
  • Firstpage
    2546
  • Lastpage
    2550
  • Abstract
    Material-selective imaging using dual energy CT (DECT) heavily relies on well-calibrated material decomposition functions. These require the precise knowledge of the detected X-ray spectrum and even if this is exactly known the reliability of DECT will suffer from scattered radiation. We propose an empirical method to determine the proper decomposition function. In contrast to other decomposition algorithms our empirical dual energy calibration (EDEC) technique does neither require knowledge of the spectrum nor of the attenuation coefficients. The desired material-selective rawdata p1 and p2 are obtained as a function of the measured attenuation data q1 and q2 (one DECT scan = two rawdata sets) using a polynomial function whose coefficients are determined using a general least squares fit based on thresholded images of a calibration phantom. Assumptions on the calibration phantom size or of its positioning are not made. Once the decomposition coefficients are determined DECT rawdata can be decomposed by simply passing them through the polynomial. To demonstrate EDEC simulations of an oval CTDI phantom, a lung phantom and a thorax phantom were carried out and a physical phantom composed of water and calcium hydroxypatite was measured with a dedicated in vivo dual source micro-CT scanner (TomoScope 30s Duo, VAMP GmbH, Erlangen, Germany). The rawdata were decomposed into its components, reconstructed and the pixel values obtained were compared to the theoretical values. The determination of the calibration coefficients with EDEC is very robust and depends only slightly on the type of calibration phantom used. Images of the said test phantoms (simulations and measurements) show a nearly perfect agreement with the theoretical mu-values and density values. Since EDEC is an empirical technique it inherently compensates for scatter components, given that the calibration phantom is of similar size as the test objects. The empirical- - dual energy calibration technique is a pragmatic, simple and reliable calibration approach that produces highly quantitative DECT images.
  • Keywords
    computerised tomography; lung; phantoms; attenuation; calcium hydroxypatite; calibration phantom; cone-beam computed tomography; decomposition coefficients; detected X-ray spectrum; dual energy CT; empirical dual energy calibration; in vivo dual source micro-CT scanner; least squares fit; lung phantom; material decomposition functions; material-selective imaging; polynomial function; scattered radiation; thorax phantom; water; Attenuation; Calibration; Computed tomography; Imaging phantoms; Optical imaging; Polynomials; Radiation detectors; Testing; X-ray detection; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2006. IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1095-7863
  • Print_ISBN
    1-4244-0560-2
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2006.354428
  • Filename
    4179542