DocumentCode
2513642
Title
Estimate the measurement uncertainty of broadband antenna (30MHz to 1GHz) calibration system
Author
Tsai, Jung-Chun ; Lin, Liang-Yang ; Tsai, Yung-Cheng ; Chen, Cheng-Chang
Author_Institution
Meas./Calibration Technol. Dept., Electron. Testing Center, Guishan Shiang, Taiwan
fYear
2010
fDate
12-16 April 2010
Firstpage
945
Lastpage
948
Abstract
According to CISPR 16-1 & ANSI C 63.4 standard requirements, to implement EMI radiated emission measurement needs to use accuracy antenna factor (AF). The Standard Site Method(SSM) of antenna calibration is most popular technology in the EMI sector. In Taiwan, the SSM calibration technology is also to set up in BSMI WUDA Antenna Site to calibrate broadband antennas (30 MHz to 1 GHz). This paper will simply describe the theme of antenna calibration, introduce the structure of this calibration site and describe the measures used to control its calibration uncertainty below 1 dB.
Keywords
broadband antennas; calibration; electromagnetic interference; EMI radiated emission measurement; SSM calibration technology; antenna calibration; antenna factor; broadband antenna; calibration site; calibration system; frequency 30 MHz to 1000 MHz; measurement uncertainty; standard site method; Antenna measurements; Attenuation measurement; Broadband antennas; Calibration; Dipole antennas; Equations; Measurement standards; Measurement uncertainty; Receiving antennas; Transmitting antennas; OATS; Standard site method; antenna calibration; ground plane; measurement uncertainty; site attenuation;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility (APEMC), 2010 Asia-Pacific Symposium on
Conference_Location
Beijing
Print_ISBN
978-1-4244-5621-5
Type
conf
DOI
10.1109/APEMC.2010.5475674
Filename
5475674