Assessment of a new CT system for small animals
Author
Redondo, S. ; Vaquero, J.J. ; Lage, E. ; Abella, M. ; Tapias, G. ; Udias, A. ; Desco, M.
Author_Institution
Med. Imaging Lab, Gregorio Maranon Hosp., Madrid
Volume
6
fYear
2006
fDate
Oct. 29 2006-Nov. 1 2006
Firstpage
3553
Lastpage
3556
Abstract
We have developed an X-ray cone beam tomograph for in vivo small-animal imaging using a flat panel detector (CMOS technology with a columnar CsI scintillator plate) and a microfocus X-ray source in a geometric configuration with 1.6 magnification and 7.5 cm2 field of view. This work presents an initial characterization of this new system. We measured the detector modulation transfer function (MTF), detector stability, system resolution, the quality of the reconstructed tomographic images and radiated dose. The system resolution was measured following the standard test method ASTM E1696-95. For image quality evaluation, we assessed signal to noise ratio (SNR) and contrast to noise ratio (CNR) with respect to radiated dose. Measurements have been performed on Hounsfield-calibrated images of quantitative phantoms. Effective dose studies have been performed introducing TLD dosimeters in representative organs (ICRU criteria) of euthanized laboratory rats for different imaging protocols. Noise measurements indicate that 50 HU can be achieved at a dose of 10 cGy. Effective dose in standard research methods is below 200 mSv, confirming that the system is appropriate for in vivo imaging. Maximum spatial resolution achieved is better than 50 microns. Experimental results on image quality phantoms as well as on in-vivo studies show that the use of CMOS flat panel is a good choice in terms of quality with respect to radiated dose.
Keywords
biological organs; computerised tomography; medical image processing; phantoms; ASTM E1696-95; CMOS technology; TLD dosimeters; X-ray cone beam tomograph; biological organ; columnar CsI scintillator plate; detector modulation transfer function; detector stability; flat panel detector; microfocus X-ray source; radiated dose; reconstructed tomographic images; small animal imaging; small animals CT system; system resolution; Animals; CMOS technology; Computed tomography; Detectors; Image quality; Imaging phantoms; In vivo; Signal resolution; Signal to noise ratio; X-ray imaging;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2006. IEEE
Conference_Location
San Diego, CA
ISSN
1095-7863
Print_ISBN
1-4244-0560-2
Electronic_ISBN
1095-7863
Type
conf
DOI
10.1109/NSSMIC.2006.353766
Filename
4179808
Link To Document