• DocumentCode
    2526985
  • Title

    Power quality management for advanced building facilities

  • Author

    Leung, John K K ; Lin, Dennis ; Fung, Francis

  • Author_Institution
    CLP Power Hong Kong Ltd., Hong Kong, China
  • fYear
    2012
  • fDate
    17-20 June 2012
  • Firstpage
    763
  • Lastpage
    768
  • Abstract
    Like other power systems in the world, most of the voltage dips in Hong Kong are caused by thunderstorms, lightning, vegetation intrusion, third party interference and heavy load switching. In some cases, voltage dip may lead to interruption of major advanced building facilities inside the building like tripping and sudden stoppage of chiller plant and lift. A number of analysis and tests were conducted to verify the ride-through capability for building facilities such as building management system (BMS) and lift in developing a practical and sustainable solution. The ride-through solution for BMS is a successful story that involves cost effective investment for improving the PQ compatibility of the susceptible equipment. Some lifts may also trip during voltage dip. Although most modern lifts are equipped with auto-restart, there were still cases where the feature was unable to function and resulted in shut-in-lift situation. Unless the lift was locked off by the operation of the safety gear in which attention by lift maintenance personnel was necessary, in most other cases the situation could be improved with suitable mitigation measures. These include remote alarm, post-voltage-dip-operation [1] and regenerative braking features. This paper describes the major initiatives formulated to meet this PQ challenge for advanced building facilities such as BMS and lift. The mitigation measures for BMS and lift combating voltage dip incident will also be presented.
  • Keywords
    building management systems; energy management systems; maintenance engineering; power supply quality; vegetation; BMS; Hong Kong; PQ compatibility; advanced building facilities; building management system; chiller plant; heavy load switching; lift maintenance personnel; post-voltage-dip-operation; power quality management; power systems; regenerative braking features; remote alarm; safety gear; shut-in-lift situation; third party interference; vegetation intrusion; voltage dips; Current measurement; Delay; Harmonic analysis; Indexes; Lead; Voltage fluctuations; Building Management System; Chiller; Direct Digital Control; Lift; Motor drive; Network Control Unit; Power quality; Regenerative braking; Ride-through; Voltage dip;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Harmonics and Quality of Power (ICHQP), 2012 IEEE 15th International Conference on
  • Conference_Location
    Hong Kong
  • ISSN
    1540-6008
  • Print_ISBN
    978-1-4673-1944-7
  • Type

    conf

  • DOI
    10.1109/ICHQP.2012.6381272
  • Filename
    6381272