DocumentCode
2529120
Title
Piezoelectric switch to activate event-driven wireless sensor node by several Hz of vibration
Author
Kobayashi, T. ; Okada, H. ; Gang, V.Z. ; Maeda, R. ; Masuda, T. ; Itoh, T.
Author_Institution
Nat. Inst. of Adv. Ind. Sci. & Technol. (AIST), Tsukuba, Japan
fYear
2011
fDate
5-9 June 2011
Firstpage
1014
Lastpage
1017
Abstract
The present study describes the MEMS-based piezoelectric switch to activate the event-driven wireless sensor node for chicken health monitoring system. We have fabricated the switch composed of “S” shaped piezoelectric cantilever and proof mass, where the resonance is 24 Hz. When the switch has been vibrated at 4, 6, 8, and 12 Hz, which is close to the chicken movement frequency, the input vibration was converted into the resonant one through superharmonic resonance leading to enough voltage to activate event-driven operation.
Keywords
condition monitoring; microsensors; piezoelectric devices; switches; wireless sensor networks; MEMS-based piezoelectric switch; chicken health monitoring system; event-driven wireless sensor node; frequency 24 Hz; piezoelectric switch; superharmonic resonance; vibration; Frequency measurement; Resonant frequency; Switches; Vibrations; Voltage measurement; Wireless communication; Wireless sensor networks; Event-driven; Piezoelectric; Superharmonic resonance; Wireless sensor network;
fLanguage
English
Publisher
ieee
Conference_Titel
Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS), 2011 16th International
Conference_Location
Beijing
ISSN
Pending
Print_ISBN
978-1-4577-0157-3
Type
conf
DOI
10.1109/TRANSDUCERS.2011.5969157
Filename
5969157
Link To Document