• DocumentCode
    2534774
  • Title

    A row-action based L1-minimization approach to robust fluorescent tomography

  • Author

    Mohajerani, Pouyan ; Behrooz, Ali ; Eftekhar, Ali A. ; Adibi, Ali

  • Author_Institution
    Sch. of Electr. & Comput. Eng., Georgia Inst. of Technol., Atlanta, GA, USA
  • fYear
    2009
  • fDate
    4-8 Oct. 2009
  • Firstpage
    345
  • Lastpage
    346
  • Abstract
    We present a row-action method based on minimization of the L1 norm for improving the accuracy of fluorescent tomography in reconstruction of fluorescent objects. The method is validated using a CW system and milk-based phantoms.
  • Keywords
    biomedical optical imaging; fluorescence; image reconstruction; medical image processing; minimisation; optical tomography; phantoms; CW system; L1 norm; fluorescent tomography; image reconstruction; milk-based phantoms; row-action based L1-minimization; Drives; Fluorescence; Image reconstruction; Laser excitation; Minimization methods; Optical imaging; Robustness; Subspace constraints; Tomography; Vectors; Medical imaging; fluorescent tomography; in-vivo imaging; molecular imaging; optical tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    LEOS Annual Meeting Conference Proceedings, 2009. LEOS '09. IEEE
  • Conference_Location
    Belek-Antalya
  • ISSN
    1092-8081
  • Print_ISBN
    978-1-4244-3680-4
  • Electronic_ISBN
    1092-8081
  • Type

    conf

  • DOI
    10.1109/LEOS.2009.5343229
  • Filename
    5343229