• DocumentCode
    2537152
  • Title

    Conversion and Comparison of the Test Results in Fully and Semi-Anechoic Chamber

  • Author

    Yu, ZHOU ; Hongbo, Tao ; Wenjian, Wang ; Shufang, Li

  • Author_Institution
    Beijing Univ. of Posts & Telecommun., Beijing
  • fYear
    2007
  • fDate
    23-26 Oct. 2007
  • Firstpage
    287
  • Lastpage
    290
  • Abstract
    This paper illustrates the test method of the radiated emission in Semi-Anechoic Chamber (SAC), and the radiated power in Fully Anechoic Chamber (FAC) between 30 MHz and 1 GHz. The test results are conversed and compared by analysis, while the correction factors that influence the performance are given.
  • Keywords
    anechoic chambers (electromagnetic); electromagnetic compatibility; anechoic chamber; electromagnetic test method; frequency 30 MHz to 1 GHz; Antenna measurements; Educational institutions; Electronic equipment testing; Erbium; Monitoring; Open area test sites; Polarization; Power measurement; Receiving antennas; Transmitting antennas; EMC; anechoic chamber; radiated emission; radiated power;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2007. EMC 2007. International Symposium on
  • Conference_Location
    Qingdao
  • Print_ISBN
    978-1-4244-1371-3
  • Electronic_ISBN
    978-1-4244-1372-0
  • Type

    conf

  • DOI
    10.1109/ELMAGC.2007.4413487
  • Filename