DocumentCode
2537499
Title
Indirect emitter temperature measurement
Author
McVey, John B. ; Hatch, G.L.
Author_Institution
Rasor Associates Inc., Sunnyvale, CA, USA
fYear
1989
fDate
6-11 Aug 1989
Firstpage
2859
Abstract
In-core tests of thermionic fuel elements that seek to determine converter performance and the extent of emitter fuel swelling require accurate knowledge of emitter temperature. A method has been developed for accurately determining emitter temperature based on fitting calculated results to the unignited-mode (diffusion mode) portion of the I -V curve. A computer-based data acquisition and analysis system that enables real-time emitter temperature determination to be done, as well as data archiving for future analysis, is described
Keywords
computerised instrumentation; data acquisition; temperature measurement; testing; thermionic conversion; I-V curve; computer-based data acquisition; emitter fuel swelling; in-core tests; indirect emitter temperature measurement; real-time emitter temperature determination; thermionic fuel elements; Atomic measurements; Electrodes; Electron mobility; Equations; Ionization; Plasma temperature; Temperature measurement; Temperature sensors; Thermal conductivity; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Energy Conversion Engineering Conference, 1989. IECEC-89., Proceedings of the 24th Intersociety
Conference_Location
Washington, DC
Type
conf
DOI
10.1109/IECEC.1989.74399
Filename
74399