Abstract
In positron emission tomography (PET) a post-filtering step may be used to reduce image noise. For that purpose a moving average filter with a Gaussian shape is frequently used. However, such a filter decreases the spatial resolution and increases the spillover between adjacent structures. These effects become important when dealing with small structures such as the carotid arteries with the aim to derive an image derived input function (IDIF). In this work, a bilateral filter which involves the anatomical information from a segmented magnetic resonance image (MRI) is proposed. To test the filter, dynamic FDG images were simulated with GATE (Geant4 Application for Tomographic Emission) for the BrainPET scanner. To evaluate the filter, the signal to noise ratio (SNR) of the IDIF was calculated. Moreover, three approaches to estimate the IDIF were examined, which were based on: i) the carotid volume of interest (VOl) average, ii) the hottest voxels per plane in carotid VOl and iii) the hottest voxels in the carotid VOl. These were evaluated with the area under the curve (AVe) as well as with partial volume coefficients. The results show that the bilateral filter increases the SNR and reduces the differences between the simulated and estimated IDIF. In conclusion, compared to moving average Gaussian filtering the proposed filter reduces the PVE and increases the SNR.
Keywords
Monte Carlo methods; biomedical MRI; blood vessels; digital filters; image denoising; medical image processing; moving average processes; positron emission tomography; BrainPET scanner; GATE; Gaussian shaped moving average filter; Geant4 Application for Tomographic Emission; IDIF; MR-BrainPET; anatomical information; bilateral filter; carotid arteries; dynamic FDG images; image derived input function; image noise reduction; magnetic resonance image; moving average Gaussian filtering; positron emission tomography; post filtering step; segmented MRI; signal to noise ratio;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location
Anaheim, CA
ISSN
1082-3654
Print_ISBN
978-1-4673-2028-3
Type
conf
DOI
10.1109/NSSMIC.2012.6551508
Filename
6551508
Link To Document