• DocumentCode
    2555122
  • Title

    Transfer impedance measurements on the shielding of a multi-pins board-to-board connector

  • Author

    De Langhe, Pascal ; Martens, Luc ; De Zutter, Daniel ; Morlion, Danny

  • Author_Institution
    Dept. of Inf. Technol., Ghent Univ., Belgium
  • fYear
    1994
  • fDate
    22-26 Aug 1994
  • Firstpage
    453
  • Lastpage
    455
  • Abstract
    A new triaxial test fixture has been developed for measuring the transfer impedance of the shield of a board-to-board or backplane connector. A lot of attention has been paid to the design of the outer and inner line of the test cell. As a reference, first transfer impedance measurements were done on a commonly used coaxial cable where a good agreement with literature results was found. Various configurations of the connector shield were further measured and compared, showing a large influence of the omission of side and bottom parts of the connector shields
  • Keywords
    cable sheathing; coaxial cables; electric connectors; electric impedance measurement; electromagnetic shielding; test facilities; backplane connector; coaxial cable; connector shield; inner line; multi-pins board-to-board connector; outer line; shielding; test cell; transfer impedance measurements; triaxial test fixture; Assembly; Backplanes; Cable shielding; Character generation; Coaxial cables; Connectors; Electromagnetic measurements; Impedance measurement; Power cables; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1994. Symposium Record. Compatibility in the Loop., IEEE International Symposium on
  • Conference_Location
    Chicago, IL
  • Print_ISBN
    0-7803-1398-4
  • Type

    conf

  • DOI
    10.1109/ISEMC.1994.385606
  • Filename
    385606