    Slit-slat collimator geometrical calibration for a PET/SPECT dual modality animal scanner

  • Author

    Xiao Deng ; Beaudoin, Jean-Francois ; Cadorette, Jules ; Naaman, Charles ; Lecomte, Roger ; Rutao Yao

  • Author_Institution
    Dept. of Nucl. Med., State Univ. of New York at Buffalo, Buffalo, NY, USA
  • fYear
    2012
  • fDate
    Oct. 27 2012-Nov. 3 2012
  • Firstpage
    3808
  • Lastpage
    3811
  • Abstract
    We developed a cost-effective dual modality PET/SPECT imaging device based on an animal PET scanner. To achieve a large axial field of view (FOV) in the SPECT imaging mode, a slit-slat collimator insert was used. The objective of this work was to assess a method that used the PET imaging capability of the scanner to calibrate the geometrical parameters of the slit-slat collimator, including the slit aperture centers (SACs), axis of rotation (A OR), and slat center positions (SCPs). To calibrate the SAC and AOR values, the inner wedge surfaces of the slit apertures were painted with a 18F solution. The slit cylinder was mounted in its SPECT setup and imaged in PET mode at multiple rotational positions. The SAC and AOR values were then estimated from the reconstructed PET images. To calibrate the SCP values, the slat assembly was mounted in its SPECT setup, with a 18F capillary line source attached to its inner tube wall and along the scanner´s axial direction, and imaged in PET mode. The axial sectional profile of the reconstructed PET image was used to estimate the SCPs. The calibrated geometrical parameters were used to generate the system matrix for SPECT image reconstruction. Phantom studies were performed. It was found that the proposed PET calibration method was easy to setup, fast to perform, and reliable.
  • Keywords
    biomedical equipment; calibration; collimators; image reconstruction; medical image processing; phantoms; single photon emission computed tomography; 18F capillary line source; AOR; PET-SPECT dual modality animal scanner; SAC; axis-of-rotation; geometrical calibration; image reconstruction; phantom; slit aperture centers; slit-slat collimator;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-2028-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2012.6551874
  • Filename
    6551874