DocumentCode
2571775
Title
Clutter reduction in echocardiography with short-lag spatial coherence (SLSC) imaging
Author
Bell, Muyinatu A Lediju ; Goswami, Robi ; Trahey, Gregg E.
Author_Institution
Dept. of Biomed. Eng., Duke Univ., Durham, NC, USA
fYear
2012
fDate
2-5 May 2012
Firstpage
1116
Lastpage
1119
Abstract
Clutter, a problematic noise artifact in echocardiography, appears as a diffuse haze that obscures endocardial borders and inhibits accurate diagnoses. Several approaches are available to reduce clutter in cardiac images, yet difficult-to-image patients still exist. We have recently developed a novel imaging method, termed short-lag spatial coherence (SLSC) imaging, that has demonstrated potential to reduce clutter in simulated and experimental data. With this technique, images are created from the same individual channel signals used to form B-mode images, but instead of applying a conventional delay-and-sum beamformer, the data are cross-correlated to measure and display differences in spatial coherence. This technique was applied to in vivo cardiac images. Individual channel signals were acquired to form matched B-mode and SLSC images of the left ventricle in fourteen human volunteers. The contrast and contrast-to-noise ratio (CNR) of the ventricle and the signal-to-noise ratio (SNR) of the endocardium were measured in the same locations in matched B-mode and SLSC images. In SLSC images created with a short-lag value equivalent to 16% of the transmit aperture, contrast and CNR was improved by 9±7 dB and 0.4±0.2, respectively, in the SLSC images. The average SNR of the endocardium was 1.7±0.4 in the SLSC images and 1.8±0.4 in the B-mode images. The presented approach demonstrates a new method for reducing clutter in cardiac images.
Keywords
array signal processing; echocardiography; image denoising; medical image processing; CNR; SLSC imaging; SNR; contrast-noise ratio; delay and sum beamformer; echocardiography clutter reduction; endocardial borders; endocardium; in vivo cardiac images; left ventricle B-mode images; left ventricle SLSC images; noise artifact; short lag spatial coherence imaging; signal-noise ratio; spatial coherence differences; Clutter; Echocardiography; Harmonic analysis; Signal to noise ratio; Spatial coherence; Ultrasonic imaging; cardiac imaging; noise reduction; ultrasound;
fLanguage
English
Publisher
ieee
Conference_Titel
Biomedical Imaging (ISBI), 2012 9th IEEE International Symposium on
Conference_Location
Barcelona
ISSN
1945-7928
Print_ISBN
978-1-4577-1857-1
Type
conf
DOI
10.1109/ISBI.2012.6235755
Filename
6235755
Link To Document