Abstract
Space charge profiles obtained in low density polyethylene under sinusoidal or square AC stress for frequencies going from DC to 10 Hz, temperature from 25 to 50degC and fields of 30 or 40 kV/mm are presented. It is shown that most of the features observed under DC stress (generation of carriers of the two polarities with non-symmetrical amount and velocity) are still active under AC stress. As a matter of fact, it is shown that a negative space charge builds up at 50degC within the whole insulation bulk even with relatively high stress frequency.
Keywords
polyethylene insulation; pulsed electroacoustic methods; space charge; AC stress; DC stress; low-density polyethylene; negative space charge; pulsed electro-acoustic method; space charge measurements; AC generators; Charge measurement; Current measurement; Frequency; Polyethylene; Pulse measurements; Pulsed electroacoustic methods; Space charge; Stress measurement; Temperature;