DocumentCode
2600467
Title
A comparative evaluation of fine regenerative and nonregenerative vector controlled drives for AC gearless elevators
Author
Kulkarni, A.B. ; Nguyen, Hien ; Gaudet, E.W.
Author_Institution
Thyssen Dover Elevator, Horn Lake, MS, USA
Volume
3
fYear
2000
fDate
2000
Firstpage
1431
Abstract
This paper presents a comparative evaluation of regenerative and nonregenerative vector controlled variable voltage variable frequency (VVVF) drives for AC gearless elevators. The study includes a detailed analysis of energy consumption, line voltage and current harmonics, elevator machine room heat generated, input power factor and peak demand for each elevator control system. The input voltage and current waveforms are presented for both regenerative and nonregenerative drives to show the clean power nature of the VVVF regenerative drive. Extensive test data from the field is also presented to validate the analysis
Keywords
AC motor drives; lifts; machine vector control; power factor; AC gearless elevators; VVVF drives; elevator control system; elevator machine room heat generated; elevator position control; energy consumption; input current waveforms; input power factor; input voltage waveforms; line current harmonics; line voltage harmonics; nonregenerative vector controlled drives; peak demand; regenerative vector controlled drives; variable voltage variable frequency drives; Control systems; Elevators; Energy consumption; Frequency; Harmonic analysis; Power generation; Power system harmonics; Reactive power; Temperature control; Voltage control;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Conference, 2000. Conference Record of the 2000 IEEE
Conference_Location
Rome
ISSN
0197-2618
Print_ISBN
0-7803-6401-5
Type
conf
DOI
10.1109/IAS.2000.882072
Filename
882072
Link To Document