• DocumentCode
    2609339
  • Title

    A Simple Method of using the Die of an Integrated Circuit to Measure the Relative Humidity Inside its Encapsulation

  • Author

    Merrett, R.P. ; Sim, S P ; Bryant, J P

  • Author_Institution
    Post Office Research Centre, Martlesham Heath, Ipswich IP5 7RE England
  • fYear
    1980
  • fDate
    29312
  • Firstpage
    17
  • Lastpage
    25
  • Abstract
    A technique (the capacitance-ratio test) is described for assessing the water content of hermetic packages containing an integrated circuit die. It is based on a theoretical analysis which shows that the frequency dependence of the capacitance between a selected pair of IC metallisation tracks can be used to derive the moisture induced component of this capacitance. A measurement on an encapsulated integrated circuit die, held at a constant temperature, is used to determine the ratio of the moisture induced capacitance and the intrinsic capacitance between metallisation tracks. By comparing this ratio with that obtained from a sample of integrated circuits exposed to a known relative humidity, the test can indicate whether the relative humidity in the package is greater or less than a specified value. The accuracy of the test is comparable with that of other moisture sensing methods for encapsulations, and its sensitivity is adequate for the control of known moisture-related failure mechanisms in integrated circuits.
  • Keywords
    Capacitance; Circuit testing; Encapsulation; Frequency dependence; Humidity measurement; Integrated circuit measurements; Integrated circuit packaging; Integrated circuit testing; Metallization; Moisture;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability Physics Symposium, 1980. 18th Annual
  • Conference_Location
    Las Vegas, NV, USA
  • ISSN
    0735-0791
  • Type

    conf

  • DOI
    10.1109/IRPS.1980.362907
  • Filename
    4208303