DocumentCode
2612456
Title
Electromigration-Induced Extrusions in Multi-Level Technologies
Author
Lloyd, J.R.
Author_Institution
IBM E. Fishkill Facility, Hopewell Junction, NY 12533
fYear
1983
fDate
30407
Firstpage
208
Lastpage
210
Abstract
It has been found that wearout failure in multilevel technologies is primarily by electromigration- induced extrusions leading to intralevel short circuits rather than by the traditionally studied open-circuit mode. Recent results are reported, with a discussion of the serious implication that this newly considered failure mode generates.
Keywords
Circuit testing; Condition monitoring; Conducting materials; Conductive films; Diodes; Glass; Resistors; Temperature; Thin film circuits; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Reliability Physics Symposium, 1983. 21st Annual
Conference_Location
Phoenix, AZ, USA
ISSN
0735-0791
Type
conf
DOI
10.1109/IRPS.1983.361985
Filename
4208506
Link To Document