DocumentCode
2615320
Title
Multimodality high resolution wrist imaging for monitoring response to therapy in rheumatoid arthritis: Instrumentation and techniques
Author
Chaudhari, Abhijit J. ; Burkett, George W. ; Bowen, Spencer L. ; Harse, Rick ; Packard, Nathan J. ; Stern, Robin L. ; Naguwa, Stanley M. ; Hunter, John C. ; Boone, John M. ; Buonocore, Michael H. ; Badawi, Ramsey D.
Author_Institution
Department of Biomedical Engineering, University of California-Davis, 95616, USA
fYear
2008
fDate
19-25 Oct. 2008
Firstpage
4840
Lastpage
4844
Abstract
Rheumatoid arthritis (RA) is a debilitating inflammatory disease which results in 9 million physician visits and 250,000 hospitalizations per year. New molecularly-targeted pharmaceuticals are available to treat this disease, but clinical examination and conventional imaging do not accurately distinguish long-term responders from non-responders to these expensive therapies. We hypothesize that longitudinal information gained from high resolution MRI, CT and PET imaging of wrists of RA patients receiving therapy will be synergistic and thus, in combination will lead to the development of new imaging metrics that will help clinicians match clinical response with active joint disease. These metrics could potentially be used to separate responders to therapy from non-responders at early time points in the course of the disease. To test this hypothesis, we aim to use a unique high resolution extremity PET/CT scanner built by UC Davis researchers and a knee coil in a 1.5T MRI whole-body scanner. A multimodality wrist restraint system (WRS) has been designed and fabricated, and is used to immobilize the wrist during and between scans. Phantom experiments have been carried out for the scanners in the presence of the WRS. No apparent image degradation due to the WRS was observed. Images from the three modalities have been rigidly registered using a fiducial marker-based approach. A repositioning study was carried out in healthy volunteers using the MRI scanner. Results from this study examining repositioning error in wrist bones look promising. Instrumentation development has been completed and proof-of-principle scans have been carried out. A clinical trial in 10 patients for monitoring response in RA has been approved by IRB and recruiting has begun in early November.
Keywords
Arthritis; Computed tomography; Diseases; High-resolution imaging; Image resolution; Instruments; Magnetic resonance imaging; Medical treatment; Monitoring; Wrist; MRI; Multimodality imaging; PET/CT; Rheumatoid arthritis; high resolution; response to therapy;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
Conference_Location
Dresden, Germany
ISSN
1095-7863
Print_ISBN
978-1-4244-2714-7
Electronic_ISBN
1095-7863
Type
conf
DOI
10.1109/NSSMIC.2008.4774327
Filename
4774327
Link To Document