• DocumentCode
    2619266
  • Title

    On-line evaluation of spatial dose-distribution by using a 15m-long plastic scintillation-fiber detector

  • Author

    Nohtomi, A. ; Sugiura, N. ; Itoh, T. ; Torii, T.

  • Author_Institution
    Atomic Energy Research, Institute, Kinki University, Osaka, Japan
  • fYear
    2008
  • fDate
    19-25 Oct. 2008
  • Firstpage
    965
  • Lastpage
    968
  • Abstract
    A 15m-long plastic scintillation fiber (PSF) detector has been applied to the on-line evaluation of spatial dose-distribution inside radiation facilities. The aim of this study is to realize the real-time measurement system which is not only simple but also reliable for monitoring use. Determination of radiation-incident points was made by the measurement of time difference that two directional signals of the scintillation light reach both ends of the PSF [so called “time-of-flight (TOF) method”]. The PSF used had practically enough sensitivity to detect both fast neutrons and gamma-rays.
  • Keywords
    Monitoring; Neutrons; Optical fibers; Plastics; Position measurement; Position sensitive particle detectors; Pulse amplifiers; Radiation detectors; Solid scintillation detectors; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
  • Conference_Location
    Dresden, Germany
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-2714-7
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2008.4774556
  • Filename
    4774556