DocumentCode
2626931
Title
A volume visualization driver in Geant4 for radiotherapy simulation
Author
Kimura, Akinori ; Sasaki, Takashi ; Tanaka, Satoshi
Author_Institution
Department of Electrical and Electronic Engineering, Ashikaga Institute of Technology, 268-1 Omae, Tochigi 326-8558 Japan
fYear
2008
fDate
19-25 Oct. 2008
Firstpage
3158
Lastpage
3161
Abstract
A volume visualization driver in Geant4 was developed in order to display a complex patient image and a calculated dose distribution in a radiotherapy simulation with an external volume visualizer. Monte Carlo simulation has been widely used for radiological simulation. In radiotherapy simulation, it applies to calculation of the dose distribution, optimization of the beam delivery system, and so on. Geant4 toolkit is utilized to build a simulator for that purpose. In that simulator, visualizer needs the volume rendering capability to display a complex volume data. However, there is no volume rendering capability in the visualization system in Geant4. The volume visualization driver extracts a patient data, calculated dose distributions, particle trajectories and geometrical information of beam delivery modules in the simulation, and then saves their information as a data file. With that data file, the external volume visualizer is able easily to display results of the simulation.
Keywords
Biomedical imaging; Computed tomography; Data visualization; Detectors; Displays; Geometry; Graphics; Medical simulation; Nuclear and plasma sciences; Physics;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
Conference_Location
Dresden, Germany
ISSN
1095-7863
Print_ISBN
978-1-4244-2714-7
Electronic_ISBN
1095-7863
Type
conf
DOI
10.1109/NSSMIC.2008.4775022
Filename
4775022
Link To Document