DocumentCode
2636796
Title
Development of a battery step voltage to determine parameters of large PMG
Author
Kuchenbecker, W.E. ; Teixeira, J.C.
Author_Institution
WEG Electr. Equipments, Brazil
fYear
2012
fDate
27-29 March 2012
Firstpage
1
Lastpage
6
Abstract
Permanent magnet generators (PMG) parameters cannot be determined by using conventional test procedures due to the impossibility to control the magnetic field created by the rotor, so that new procedures need to be developed and standardized taking into account that the power of new PMG for large wind farms is increasing as is the need for power in laboratory facilities. A DC step voltage is an equivalent method that, analyzed with others, makes the determination of important PMG parameters possible. To validate the new method, it was also applied to a well know conventional synchronous machine using the IEC and IEEE methods. The comparison of results showed that de DC step voltage can help the parameter identification of large PMG for wind applications.
Keywords
cells (electric); permanent magnet generators; synchronous generators; wind power plants; DC step voltage; IEC methods; IEEE methods; PMG parameters; battery step voltage; laboratory facility; magnetic field control; permanent magnet generators; rotor; synchronous machine; wind farms; DC Step Voltage Test; Permanent Magnet Generators (PMG); wind energy;
fLanguage
English
Publisher
iet
Conference_Titel
Power Electronics, Machines and Drives (PEMD 2012), 6th IET International Conference on
Conference_Location
Bristol
Electronic_ISBN
978-1-84919-616-1
Type
conf
DOI
10.1049/cp.2012.0166