• DocumentCode
    2643355
  • Title

    Shielding effectiveness and S21 of a rectangular enclosure with aperture and wire penetration

  • Author

    Sapuan, Syarfa Zahirah ; Jenu, Mohd Zarar Mohd

  • Author_Institution
    Center for Electromagn. Compatibility, Univ. Tun Hussein Onn Malaysia, Parit Raja
  • fYear
    2007
  • fDate
    4-6 Dec. 2007
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    Shielding effectiveness is a major problem to prevent electronic products from emission and radiation. This paper is written to present the measurement of shielding effectiveness (SE) and S21 for such enclosure at frequencies below 1GHz. The measurement results indicate that a wire or cable penetrating into an enclosure has impact to the shielding effectiveness. The coupling between a wire penetration and a detector inside the enclosure show good agreement between experiment and simulation. The different length and direction of a wire penetration were used to interpret the theory. All results indicate the same resonant frequency approximately 707.1MHz for a 300 x 120 x 300 mm enclosure.
  • Keywords
    cable shielding; electromagnetic shielding; radiation hardening (electronics); wires (electric); cable penetration; rectangular enclosure; shielding effectiveness; wire penetration; Antenna measurements; Apertures; Cable shielding; Electromagnetic compatibility; Electromagnetic interference; Electromagnetic measurements; Electromagnetic radiation; Electromagnetic radiative interference; Frequency measurement; Wire; S21; Shielding Effectiveness; enclosure; wire penetration;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Electromagnetics, 2007. APACE 2007. Asia-Pacific Conference on
  • Conference_Location
    Melaka
  • Print_ISBN
    978-1-4244-1434-5
  • Electronic_ISBN
    978-1-4244-1435-2
  • Type

    conf

  • DOI
    10.1109/APACE.2007.4603927
  • Filename
    4603927