• DocumentCode
    2646720
  • Title

    Performance evaluation of a microchannel plate based x-ray camera with a reflecting grid

  • Author

    Visco, A. ; Harding, E.C. ; Drake, R.P. ; Lafferty, D.C. ; Rathore, G.K.

  • Author_Institution
    Michigan Univ., Ann Arbor, MI
  • fYear
    2006
  • fDate
    4-8 June 2006
  • Firstpage
    154
  • Lastpage
    154
  • Abstract
    Summary form only given. Microchannel plates (MCPs) are used in a variety of imaging systems as a means of amplifying the incident radiation. Using a microchannel plate mount recently developed at the University of Michigan, the effects of a metal reflecting grid are explored. Employing the reflecting grid, we create a potential difference above the MCP input surface that forces ejected electrons back into the pores, which may prove to increase the quantum efficiency of the camera. Using a characterized X-ray source, we investigate the changes in the pulse height distribution, modular transfer function, and quantum efficiency of MCPs caused by the introduction of the reflecting grid
  • Keywords
    X-ray imaging; microchannel plates; pulse height analysers; transfer functions; X-ray camera; X-ray source; imaging systems; metal reflecting grid; microchannel plates; modular transfer function; pulse height distribution; quantum efficiency; Cameras; Electrons; Laboratories; Microchannel; National security; Optical imaging; Transfer functions; US Department of Energy; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science, 2006. ICOPS 2006. IEEE Conference Record - Abstracts. The 33rd IEEE International Conference on
  • Conference_Location
    Traverse City, MI
  • Print_ISBN
    1-4244-0125-9
  • Type

    conf

  • DOI
    10.1109/PLASMA.2006.1707026
  • Filename
    1707026