  • Abstract
    This paper presents a detailed lumped parameter (LP) thermal model of an armature slot in a permanent magnet synchronous machine for traction applications. The model is used to investigate the temperature distribution in the slot after a turn-to-turn failure occurs. Steady-state analyses are conducted and a good agreement is found with FEM thermal simulations. The LP model is modified into a transient model and transient thermal analysis are conducted to predict the processing damage in the slot, which eventually might lead to a turn-to-tooth (ground) failure.
  • Keywords
    fault location; finite element analysis; machine windings; permanent magnet machines; synchronous machines; temperature distribution; thermal analysis; FEM thermal simulation; LP thermal model; armature slot; lumped parameter thermal model; permanent magnet synchronous machine; steady state analysis; temperature distribution; traction application; transient thermal analysis; winding turn-to-turn fault; Atmospheric modeling; Coils; Conductors; Heat transfer; Insulation; Integrated circuit modeling; Teeth; Synchronous machines; permanent magnet; thermal modeling; turn-to-turn faults; winding failures;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines (ICEM), 2010 XIX International Conference on
  • Conference_Location
    Rome
  • Print_ISBN
    978-1-4244-4174-7
  • Electronic_ISBN
    978-1-4244-4175-4
  • Type

    conf

  • DOI
    10.1109/ICELMACH.2010.5608010
  • Filename
    5608010