DocumentCode
2650039
Title
Thermal analysis of a winding turn-to-turn fault in PM synchronous machine
Author
Smeets, J.P.C. ; Soulard, J. ; Lomonova, E.A.
Author_Institution
Electromech. & Power Electron. group, Eindhoven Univ. of Technol., Eindhoven, Netherlands
fYear
2010
fDate
6-8 Sept. 2010
Firstpage
1
Lastpage
6
Abstract
This paper presents a detailed lumped parameter (LP) thermal model of an armature slot in a permanent magnet synchronous machine for traction applications. The model is used to investigate the temperature distribution in the slot after a turn-to-turn failure occurs. Steady-state analyses are conducted and a good agreement is found with FEM thermal simulations. The LP model is modified into a transient model and transient thermal analysis are conducted to predict the processing damage in the slot, which eventually might lead to a turn-to-tooth (ground) failure.
Keywords
fault location; finite element analysis; machine windings; permanent magnet machines; synchronous machines; temperature distribution; thermal analysis; FEM thermal simulation; LP thermal model; armature slot; lumped parameter thermal model; permanent magnet synchronous machine; steady state analysis; temperature distribution; traction application; transient thermal analysis; winding turn-to-turn fault; Atmospheric modeling; Coils; Conductors; Heat transfer; Insulation; Integrated circuit modeling; Teeth; Synchronous machines; permanent magnet; thermal modeling; turn-to-turn faults; winding failures;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines (ICEM), 2010 XIX International Conference on
Conference_Location
Rome
Print_ISBN
978-1-4244-4174-7
Electronic_ISBN
978-1-4244-4175-4
Type
conf
DOI
10.1109/ICELMACH.2010.5608010
Filename
5608010