• DocumentCode
    2650771
  • Title

    Double Mode Fuzzy Control of Gas Drainage System for Coal Local Ventilator

  • Author

    Ma, Xian-Min

  • Author_Institution
    Coll. of Electr. & Control Eng., Xian Univ. of Sci. & Technol., Xian
  • fYear
    2009
  • fDate
    1-2 Feb. 2009
  • Firstpage
    211
  • Lastpage
    215
  • Abstract
    Coal gas drainage out of the mine excavation workspace is the urgent problem to be solved for safe production, a novel double mode fuzzy control strategy of gas drainage system for the coal local ventilator is proposed in the paper. One fuzzy control mode is used in normal aeration state. The other mode is adopted to expel the gas from the mine well, when the gas strength is abnormal. The switching condition of the two modes is discussed, the air flow press distribution in digging laneway is analyzed, and the fuzzy control system is designed. The theory analysis and experiment results show that the suggested double mode fuzzy control schemes are transferred smoothly and the speed of local ventilator is adjusted according to the gas variable concentration in both the normal aeration and abnormal ventilation state, which assures the safety of coal mining.
  • Keywords
    coal gasification; fuzzy control; mining; safety; ventilation; air flow press distribution; coal gas drainage system; coal local ventilator; coal mining; double mode fuzzy control; mine excavation workspace; safe production; Air safety; Asia; Control systems; Explosions; Fuzzy control; Informatics; Product safety; Production systems; Robotics and automation; Ventilation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Informatics in Control, Automation and Robotics, 2009. CAR '09. International Asia Conference on
  • Conference_Location
    Bangkok
  • Print_ISBN
    978-1-4244-3331-5
  • Type

    conf

  • DOI
    10.1109/CAR.2009.67
  • Filename
    4777227