Double Mode Fuzzy Control of Gas Drainage System for Coal Local Ventilator
Author
Ma, Xian-Min
Author_Institution
Coll. of Electr. & Control Eng., Xian Univ. of Sci. & Technol., Xian
fYear
2009
fDate
1-2 Feb. 2009
Firstpage
211
Lastpage
215
Abstract
Coal gas drainage out of the mine excavation workspace is the urgent problem to be solved for safe production, a novel double mode fuzzy control strategy of gas drainage system for the coal local ventilator is proposed in the paper. One fuzzy control mode is used in normal aeration state. The other mode is adopted to expel the gas from the mine well, when the gas strength is abnormal. The switching condition of the two modes is discussed, the air flow press distribution in digging laneway is analyzed, and the fuzzy control system is designed. The theory analysis and experiment results show that the suggested double mode fuzzy control schemes are transferred smoothly and the speed of local ventilator is adjusted according to the gas variable concentration in both the normal aeration and abnormal ventilation state, which assures the safety of coal mining.
Keywords
coal gasification; fuzzy control; mining; safety; ventilation; air flow press distribution; coal gas drainage system; coal local ventilator; coal mining; double mode fuzzy control; mine excavation workspace; safe production; Air safety; Asia; Control systems; Explosions; Fuzzy control; Informatics; Product safety; Production systems; Robotics and automation; Ventilation;
fLanguage
English
Publisher
ieee
Conference_Titel
Informatics in Control, Automation and Robotics, 2009. CAR '09. International Asia Conference on
Conference_Location
Bangkok
Print_ISBN
978-1-4244-3331-5
Type
conf
DOI
10.1109/CAR.2009.67
Filename
4777227
Link To Document