• DocumentCode
    2655168
  • Title

    The Sidelighter: A New Dead-Zone Free Distance to Fault Fiber Optic Cable Measurement System

  • Author

    Paolella, Arthur

  • Author_Institution
    Artisan Labs. Corp., Chalfont, PA
  • fYear
    2006
  • fDate
    12-14 Sept. 2006
  • Firstpage
    32
  • Lastpage
    33
  • Abstract
    We have shown a method of locating faults in fiber using a new Sidelighter module that easily connects to popular microwave analyzers. The Sidelighter can be used in the field as it is compact and battery operated. Using the Sidelighter allow users to test RF and optical cables in one system. We have achieved 10 cm measurement resolution and can located failures in fibers at distances of up to 1 Km
  • Keywords
    measurement systems; microwave measurement; network analysers; optical cables; optical fibre testing; Sidelighter module; dead-zone free distance; fault location; fiber optic cable measurement system; microwave analyzers; optical cables testing; Antenna measurements; Connectors; Microwave measurements; Optical fiber cables; Optical fiber devices; Optical fiber testing; Optical fibers; Optical losses; Optical reflection; Performance analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Avionics Fiber-Optics and Photonics, 2006. IEEE Conference
  • Conference_Location
    Annapolis, MD
  • Print_ISBN
    1-4244-0408-8
  • Type

    conf

  • DOI
    10.1109/AVFOP.2006.1707486
  • Filename
    1707486